Proprietary engineering. Integrated biological treatment. Advanced water reuse.
MAK HBR™ (Hybrid Bio Reactor) is a proprietary sewage treatment platform developed by MAK India Limited. It integrates MAK HDC, MAK UFF, MAK-ABD™ Anaerobic Biodigester, DO-controlled aerobic treatment, MAK Fine Filter and optional advanced polishing technologies into a unified treatment system.
The technology is designed to reduce sludge accumulation, support stable biological treatment, optimize selected operating functions and produce treated water suitable for intended reuse applications when the required standards are achieved.
One system. Eight stages.
- Sewage inlet & screening
- Receiving tank + MAK HDC
- MAK UFF: inert and grit separation
- MAK-ABD™ anaerobic digestion
- DO-controlled aerobic treatment
- Filter feed tank + MAK Fine Filter
- Optional UF / UV / AOP / chlorination
- Treated water for approved reuse
From incoming sewage to reusable treated water.
Treatment begins with preliminary screening and wastewater collection. MAK HDC supports pretreatment, while MAK UFF separates inert and grit materials before the biological stages. MAK-ABD™ anaerobic processing and DO-controlled aerobic treatment support organic matter degradation and stabilization. The effluent then passes through filtration and, where required, additional polishing and disinfection.
MAK HDC technology
Hydro Dynamic Cavitation – proprietary pretreatment innovation
The MAK HDC device applies a hydrodynamic treatment principle to support wastewater pretreatment and biodegradability enhancement. It is integrated ahead of subsequent treatment stages.
Key functions
- Hydrodynamic wastewater pretreatment
- Support for biodegradability enhancement
- Integration with downstream biological treatment
- Proprietary engineering within the MAK HBR™ process
MAK UFF technology
Reducing inert loads before biological treatment
MAK UFF is a proprietary unit designed to separate and collect sand, grit and other inert matter before wastewater enters the biological stages. Reducing inert loading helps limit unwanted material accumulation in downstream treatment units.
Key advantages
- Grit and inert separation
- Reduction of inert loading
- Protection of downstream process stages
- Integrated pretreatment arrangement
MAK-ABD™ anaerobic treatment
Harnessing beneficial bacteria for biological digestion
The MAK-ABD™ Anaerobic Biodigester uses biological processes to support breakdown and stabilization of biodegradable organic matter. It integrates anaerobic digestion with downstream controlled aerobic treatment and builds upon MAK’s ABD-based sanitation experience.
Key advantages
- Biological organic matter degradation
- Anaerobic stabilization
- Integration with MAK AMI biological technology
- Reduced sludge-handling objectives
DO-controlled aerobic treatment
Intelligent aeration for optimized sewage treatment
The aerobic treatment stage uses dissolved oxygen (DO) monitoring and control to support biological stabilization and optimize oxygen delivery. DO-based controls allow aeration equipment to respond to operating requirements within the designed control logic.
Key features
- DO monitoring
- Controlled oxygen supply
- Optimized blower operation
- Biological process stabilization
- Integration with PLC-based automation
MAK Fine Filter
Dedicated filtration for improved treated-water quality
The MAK Fine Filter provides an additional filtration stage to improve effluent quality following biological treatment. Filtered water may subsequently undergo selected polishing and disinfection based on the required final quality.
Key functions
- Dedicated tertiary filtration
- Improvement of treated-water quality
- Integration with advanced polishing stages
- Support for intended reuse applications
Advanced water polishing & disinfection
Treatment options tailored to water reuse requirements
MAK HBR™ offers configurable advanced treatment technologies. Selection depends on wastewater quality, final treated-water requirements and project specifications.
Ultrafiltration (UF)
Additional membrane-based filtration.
UV system
Ultraviolet disinfection.
MAK AOP
Advanced oxidation and supplementary polishing.
Chlorination
Chemical disinfection.
Combined treatment
Multiple barriers selected for the required application.
Important: not every configuration requires all polishing technologies.
Smart automation & process control
Smarter monitoring. Simplified operations.
MAK HBR™ incorporates DO-controlled aeration and PLC-based monitoring to support process control and day-to-day operation. Optional SCADA integration can provide expanded monitoring and supervision according to project requirements.
Control features
Engineering each STP around its application.
MAK HBR™ designs are developed according to site-specific technical requirements. The assessment considers the following factors:
Design flow in KLD
Influent characteristics
Hydraulic and organic loading
Site dimensions
Reuse objectives
Relevant standards
Automation scope
Anticipated operating requirements
A project-specific technical assessment determines the final configuration and equipment selection.
Request a technical assessmentMBR vs SBR vs MBBR vs MAK HBR™
Understanding the difference in sewage treatment technologies
Conventional treatment systems use different biological treatment and separation approaches.
The MAK HBR™ platform is positioned around the combination of proprietary pretreatment, clarifier-free process design, sludge minimization, smart aeration and configurable water reuse.
Actual footprint, lifecycle cost, sludge generation and effluent performance must be evaluated against project-specific design conditions.